6. Secure the ground wire to the ship's ground.
The figures shown below are examples for grounding.
Ex.1
Silicone rubber
Ground wire
7. Secure the cable assembly to the cable cover with the cable ties (local supply) as
shown in the figure below.
If the cable is run through a
If the cable is run through a
radar mast and the bottom of the
radar mast and the bottom of the
unit, fix the cable to this cable
unit, fix the cable to this cable
clamp.
clamp.
Power/LAN cable
Power/LAN cable
8. Reattach the cable cover.
9. Connect the LAN connector of the cable assembly to a LAN port on the FURUNO
Multi Function Display or Ethernet HUB.
Note 1: Do not connect the LAN connector to on-board LAN.
Ethernet HUB
OR
FURUNO Multi Function Display
Ex.2
Hex. bolt
Flat washer
Ground wire
Flat washer
Spring washer
Hex. nut
Cable assembly
Cable assembly
Fix the cable to this cable
Fix the cable to this cable
clamp, using a cable tie.
clamp, using a cable tie.
Cable cover - bottom view
LAN connector
1. INSTALLATION AND WIRING
Silicone rubber
Hex. nut
Weld here.
Ground wire from
Ground wire from
the ship's ground
the ship's ground
Ground wire from
Ground wire from
the antenna unit
the antenna unit
Cable assembly
Spring washer
Flat washer
Hex. nut