Full Machine Calibration

Full machine calibration must be completed in the
proper sequence when the ALC-1000 circuit board
(TCON) in the ground control box has been
replaced or the turntable level sensor (SCON) has
been replaced.
How to Fully Calibrate the
Machine
Calibration procedures shall only be completed by
qualified technicians that have Genie factory
service training.
Tip-over hazard. Failure to
calibrate the machine in the
proper sequence could cause
the machine to tip over resulting
in death or serious injury.
Note: A digital level will be required to perform this
procedure.
Note: A kit is available through Genie Product
Support (Genie part number 58351). This kit
includes a digital level with a magnetic base and
cable harnesses.
Note: Use the following chart to identify the
description of each LCD screen control button used
in this procedure.
Plus
Minus
82
Previous
Enter
ZX®-135/70
Note: Start this procedure with the booms in the
fully stowed position and the axle retracted.
Full machine calibration must be completed in the
following sequence:
• Select engine configuration. Refer to Repair
Section, Display Module. Unit of Measure
and Language.
• Joysticks. Refer to Repair Procedure, How
to Calibrate a Joystick.
• Turntable level sensor. Refer to Repair
Procedure, How to Calibrate the Turntable
Level Sensor.
• Platform level sensor. Refer to Repair
Procedure, How to Calibrate the Platform
Level Sensor.
• Axle angle sensors. Refer to Repair
Procedure, How to Calibrate the Axle Angle
Sensors.
• Steer sensors. Refer to Repair Procedure,
How to Calibrate All Steer Sensors.
• Secondary boom angle sensor. Refer to
Repair Procedure, How to Calibrate the
Secondary Boom Angle Sensor.
• Primary boom angle sensor. Refer to Repair
Procedure, How to Calibrate the Primary
Boom Angle Sensor.
• Jib boom bellcrank angle sensor. Refer to
Repair Procedure, How to Calibrate the Jib
Boom Bellcrank Sensor.
• Select option configuration. Refer to Repair
Section, Display Module. Options.