Maintenance
9.3 Restoring the delivery state
Restore delivery state of the CPU 1515SP PC (F) with the Restore DVD
Before the restore
1. Switch off the power supply of the CPU.
2. Remove all USB devices from the CPU.
3. Connect a DVD drive with restore DVD to a USB interface of the CPU.
4. Switch on the power supply of the CPU.
→ The CPU is started.
5. Press <F12> to start the Boot Manager.
6. Select the list entry for the DVD drive in the Boot Manager.
7. After the prompt, confirm the start by pressing any key.
→ The loading process is displayed (Windows logo).
→ The SIMATIC Restore menu opens.
– Select a language.
– Select "CPU1515SP PC (F)" or "CPU1515SP PC (F) + HMI".
– Select the option "Completely restore system drive".
After the restore
1. Exit the Restore menu.
2. Remove all USB devices.
3. Proceed as described in Initial commissioning (Page 50).
Further procedure
● Reconnect the USB devices.
● Install the license keys.
94
→ The original software is restored on Partition C:, Partition D: is deleted.