Advertisement

Rule for exclusion list
The following sequence applies if you define exclusions for files and folders that do not yet
exist:
● Defining exclusions
● Restart CPU 1515SP PC (F)
● Create file/folder
Display of the partition size with activated FBWF
The partition size displayed in the Explorer does not correspond with the actual size when
the FBWF is active. The size displayed is derived from the amount of memory occupied on
the partition and from memory released by the FBWF. After the maximum size of the overlay
was reached, a message is output warning of insufficient space on the partition.
Reference
Additional information on FBWF is available on the Internet
us/library/ff794219(v=winembedded.60).aspx).
Additional information on the topic of partitions is available in the Change partitioning
(Page 85) chapter.
CPU 1515SP PC (F)
Manual, 05/2017, A5E32701806-AC
8.5 Protective functions for data carriers
(http://msdn.microsoft.com/en-