Initial commissioning an open controller
The basic settings, user name, administrator password and IP address are prompted for
during initial power-up of your CPU 1515SP PC (F). The device is then automatically set up
for the operating system that is installed on the CFast card. Restart the device after the
operating system has been set up.
Note
The initial commissioning is not possible with a Multitouch panel, as the Multitouch driver is
only available after the installation of the operating system.
User name, computer name, password
When you enter a "User name", this is suffixed with "-PC" under "Computer name". The
computer name must not exceed 15 characters.
Note
This user has administrator rights!
For security reasons, enter a password for this user (administrator).
IP address
The IP address (192.168.1.1) and the subnet mask (255.255.255.0) for the X2 interface are
pre-set in the logon dialog.
You use the buttons to make your changes or to retain the pre-set values.
Note
The initial TIA Portal download must be performed using set IP address via the GB Ethernet
interface X2 in order that the PROFINET interface X1 and the hardware configuration are
correctly assigned.
CPU 1515SP PC (F)
Manual, 05/2017, A5E32701806-AC
Commissioning
7.2 Initial commissioning
51