Mechanical ambient conditions
The table below shows the mechanical ambient conditions in the form of sinusoidal
oscillations.
Table 10- 8
Frequency band
5 ≤ f ≤ 8.4 Hz
8.4 ≤ f ≤ 150 Hz
10 ≤ f ≤ 60 Hz
60 ≤ f ≤ 1000 Hz
Test of mechanical ambient conditions
The table below provides important information with respect to the type and scope of the test
of ambient mechanical conditions.
Table 10- 9
Test of mechanical ambient conditions
Condition tested
Test Standard
Vibration
Vibration test accord-
ing to IEC 60068-2-6
(sine)
Shock
Shock, tested accord-
ing to IEC 60068-2-27
CPU 1515SP PC (F)
Manual, 05/2017, A5E32701806-AC
Mechanical ambient conditions
CPU 1515SP PC (F)
3.5 mm amplitude
1 g constant acceleration
0.35 mm amplitude
1 g constant acceleration (with BusAdapter BA 2×RJ45)
2 g constant acceleration (with BusAdapter BA 2×FC)
Comment
Type of oscillation: Frequency sweeps with a rate of change of 1 oc-
tave/minute.
BA 2×RJ45
5 Hz ≤ f ≤ 8.4 Hz, 3.5 mm constant amplitude
8.4 Hz ≤ f ≤ 150 Hz, 1 g constant acceleration
BA 2×FC
10 Hz ≤ f ≤ 60 Hz, 0.35 mm constant amplitude
60 Hz ≤ f ≤ 1000 Hz, 2 g constant acceleration
Duration of vibration: 10 frequency sweeps per axis in each of 3 vertically
aligned axes
Type of shock: Half-sine
Shock intensity: 150 m/s
Direction of shock: 3 shocks in each direction (+/-) at each of 3 vertically
aligned axes
10.4 Mechanical and climatic ambient conditions