Page 2
___________________ Analog input module AI 8xU BA Preface (6ES7134-6FF00-0AA1) ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Wiring up ET 200SP Analog input module AI 8xU BA ___________________ Parameters/address space (6ES7134-6FF00-0AA1) ___________________ Interrupts/diagnostics alarms Manual ___________________ Technical specifications ___________________ Parameter data record Representation of analog ___________________ values...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
Documentation guide The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Basic information The system manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP.
Page 7
Documentation guide Manual Collection ET 200SP The Manual Collection contains the complete documentation on the SIMATIC ET 200SP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (http://support.automation.siemens.com/WW/view/en/84133942). My Documentation Manager The My Documentation Manager is used to combine entire manuals or only parts of these to your own manual.
Product overview Properties Article number 6ES7134-6FF00-0AA1 View of the module ① ⑦ Module type and name Function class ② ⑧ LED for diagnostics Color coding module type ③ ⑨ 2D matrix code Function and firmware version ④ ⑩ Wiring diagram Color code for selecting the color identification labels ⑤...
Page 9
● Color identification labels ● Reference identification label ● Shield connector See also You can find more information on accessories in the ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) system manual. Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
2-wire connection. You can find information on wiring the BaseUnit in the ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) system manual. Note The load group of the module must begin with a light-colored BaseUnit. Keep this in mind also during the configuration.
Page 11
Wiring up 3.1 Wiring and block diagram Connection: Voltage measurement 2-wire connection The following figure shows the block diagram and an example for the terminal assignment of the analog input module AI 8xU BA on the BaseUnit BU type A0/A1. ①...
Parameters/address space Measuring types and ranges The analog input module AI 8xU BA has the following measuring ranges: Table 4- 1 Measuring ranges Measurement type Measuring range Resolution Voltage 0 to 10 V 15 bits ±10 V 16 bits including sign You will find the tables of the measuring ranges as well as overflow, overrange, etc., in the section Representation of analog values (Page 29).
Parameters/address space 4.2 Parameters Parameters AI 8xU BA parameters The effective range of the configurable parameters depends on the type of configuration. The following configurations are possible: ● Central operation with an ET 200SP CPU ● Distributed operation on PROFINET IO in an ET 200SP system ●...
Page 14
Parameters/address space 4.2 Parameters Parameter Range of values Default Reconfigura- Effective range with configura- tion in RUN tion software, e.g. STEP 7 (TIA Portal) GSD file GSD file PROFINET PROFIBUS DP Interference frequency 50 Hz (60 ms) Channel Module 60 Hz (50 ms) •...
Parameters/address space 4.3 Explanation of the parameters Explanation of the parameters Diagnostics: No supply voltage L+ Enabling of the diagnostics for no or insufficient supply voltage L+. Diagnostics: Overflow Enabling of the diagnostics when the measured value exceeds the overrange. Diagnostics: Underflow Enabling of the diagnostics when the measured value falls below the underrange.
Page 16
BaseUnits are supplied via the light-colored BaseUnits. The potential group ends with a new light-colored BaseUnit or the end of the station. See also ET 200SP Distributed I/O System (http://support.automation.siemens.com/WW/view/en/58649293) Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
Parameters/address space 4.4 Address space Address space Address space The figure below shows the assignment of the address space for AI 8×U BA. Figure 4-2 Address space of AI 8×U BA Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
Interrupts/diagnostics alarms Status and error displays LED displays The figure below shows the LED displays of the AI 8xU BA. ① DIAG (green/red) ② Channel status (green) ③ PWR (green) Figure 5-1 LED displays Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
Page 19
Interrupts/diagnostics alarms 5.1 Status and error displays Meaning of the LEDs The following tables contain the meaning of the status and error displays. Corrective measures for diagnostics alarms can be found in section Diagnostics alarms (Page 20). DIAG LED Table 5- 1 Error display of the DIAG LED DIAG LED Meaning...
Interrupts/diagnostics alarms 5.2 Interrupts Interrupts The analog input module AI 8×U BA supports diagnostics interrupts. Diagnostic interrupt The module generates a diagnostic interrupt at the following events: ● Channel temporarily unavailable ● Low limit violated ● High limit violated ● Error ●...
Technical specifications Technical specifications Technical specifications of the AI 8×U BA 6ES7134-6FF00-0AA1 Product type designation ET 200SP, 8xU Basic General information Firmware version V1.0 FW update possible • Usable BaseUnits BU type A0, A1 Color code for module-specific color identification CC02 label Product function...
Page 22
Technical specifications 6.1 Technical specifications 6ES7134-6FF00-0AA1 Address area Address space per module Address space per module, max. 16 bytes Analog inputs Number of analog inputs 8; single-ended Maximum permitted input voltage for voltage input 30 V (destruction limit) Cycle time (all channels), min. 1 ms;...
Page 23
75 V DC/60 V AC (basic insulation) Insulation Insulation tested with 707 V DC (type test) Dimensions Width 15 mm Weights Weight, approx. 31 g Dimension drawing See the manual ET 200SP BaseUnits (http://support.automation.siemens.com/WW/view/en/59753521) Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
Parameter data record Dependencies when configuring with GSD file When configuring the module with a GSD file, remember that the settings of some parameters are dependent on each other. Configuring with a PROFINET GSD file The table lists the properties and their dependencies on the measurement type and measuring range for PROFINET.
Parameter data record A.2 Parameter assignment and structure of the parameter data record Parameter assignment and structure of the parameter data record Parameter assignment in the user program The module can be re-configured in RUN (for example, the voltage or current values of selected channels can be changed in RUN without having an effect on the other channels).
Page 26
Parameter data record A.2 Parameter assignment and structure of the parameter data record Structure of data record 128 Note Channel 0 contains the diagnostics for the entire module. Figure A-1 Structure of data record 128 Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Manual, 03/2015, A5E34941660-AA...
Page 27
Parameter data record A.2 Parameter assignment and structure of the parameter data record Header information The figure below shows the structure of the header information. Figure A-2 Header information Parameters The figure below shows the structure of the parameters for channels 0 to 7. Enable a parameter by setting the corresponding bit to "1".
Page 28
Parameter data record A.2 Parameter assignment and structure of the parameter data record Figure A-3 Structure of byte x to x+17 for channels 0 to 7 Codes for measurement types The following table contains the codes for the measurement types of the analog input module.
Representation of analog values Measured value resolution The resolution of the analog values differs depending on the analog module and its parameter assignment. Each analog value is written left aligned to the tags. The bits marked with "x" are set to "0". Table B- 1 Resolution of the analog values Resolution in bits...
Representation of analog values B.1 Representation of input ranges Representation of input ranges In the following tables, you can find the digitized representation of the bipolar and unipolar input ranges. The resolution is 16 bits. Table B- 2 Bipolar input ranges Dec.
Representation of analog values B.2 Representation of analog values in voltage measuring ranges Representation of analog values in voltage measuring ranges The following tables list the decimal and hexadecimal values (codes) of the possible voltage measuring ranges. Table B- 4 Voltage measuring range ±10 V Values Voltage measuring range...