Parameter ID
Adjustment range
p2110
0 ... 1
p2111
0 ... 2
Obstruction and reversing parameters
Table 4- 36
Obstruction and reversing parameters (general)
Parameter ID
Adjustment range
General
p3850
Bit x = 1 ≙ function
1)
activated
Bit x = 0 ≙ function
deactivated
Expert parameters, see Section Expert configuration (Page 75).
1)
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Factory set-
Unit
ting
1
0
Factory
Unit
setting
0x00FF
4.9 Operation and configuration of the control unit
Description
As of V1.10: Direction of rotation of the pulse encod-
er 1 = normal, 0 = inverse
As of V1.10: Status of the basic parameter editors:
Read:
0 = Basic parameter editor is not running,
1 = Basic parameter editor active
Write:
0 = Close basic parameter editor
1 = Start Basic parameter editor
2 = Transfer data to basic parameter editor
Description
Function control
Bit 0 ≙ stop obstruction detection in the closing di-
rection
Bit 1 ≙ force obstruction detection in the closing
direction
Bit 2 ≙ obstruction counter in the closing direction
Bit 3 ≙ slow obstruction approach in the closing
direction
Bit 4 ≙ stop obstruction detection in the opening
direction
Bit 5 ≙ force obstruction detection in the opening
direction
Bit 6 ≙ obstruction counter in the opening direction
Bit 7 ≙ slow obstruction approach in the opening
direction