Siemens SIDOOR ATD401W System Manual page 123

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

LED signals
The following five status LEDs are available on the PROFIBUS module:
LED
Color
Description
H1
Green
Relay K1 picked up
LED H1 switches on when the controller has detected the
CLOSED position and the pulse generator ceases to out-
put pulses. The LED H1 is controlled by the basic module
(signal X200.11).
H2
Green
Relay K2 picked up
LED H2 switches on when the current distance of the door
to the OPEN position falls below 2 cm and the relay has
switched on. The LED H2 is controlled by the basic module
(signal X200.9).
H3
Green
Valid incoming telegram
LED H3 is controlled by the basic module (signal X200.12),
and indicates the communication status. The LED flashes
to indicate incoming, valid telegrams. Each signal change
stands for such a telegram.
H400
Red
"Bus error" PROFIBUS communication disrupted
The H400 LED flashes red in the event of PROFIBUS
communication errors.
H401
Red
"Group error" internal communication disrupted
The H401 LED flashes red in the event of internal commu-
nication errors. Extended PROFIBUS diagnostic data is
being transferred
H402
Green
Power on
LED H401 lights a continuous green after Power on.
H403
Yellow
Internal communication to main controller
LEDs H403 and H404 toggle each time after the master
H404
Yellow
has sent or received an error-free telegram.
H405
Yellow
Boot
H700
Orange P5V_ISO (X705.6) = OK
H701
Yellow
P5V = OK
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
4.5 Relay and fieldbus interfaces
Position
Controllers
123