(4) Place the machine the right way up.
(5) Remove the three screws and two screws (A) from the upper cover ASSY.
(6) Remove the upper cover ASSY from the under cover.
Note: The screws (A) are screw, bind B M2.6x4. Other screws are taptite, bind B
M2.6x6.
Fig. 3.1-9 Removing the Upper Cover ASSY (3)
(7) Turn the upper cover ASSY upside down.
(8) Remove the filament tape which secures the harness of the tape sensor PCB ASSY.
Tape sensor PCB
ASSY harness
Filament tape
Fig. 3.1-10 Removing the Upper Cover ASSY (4)
Screws (A)
III- 10
Screws
Upper cover ASSY
Under cover