Brother QL-1060N Service Manual page 103

P-touch
Hide thumbs Also See for QL-1060N:
Table of Contents

Advertisement

(2) Push the cover sensor arms L & R and media sensors, and check that the message
in the "Results" column is changed to "on" or "off". (Refer to Fig. 12.)
After checking each sensor, "Undo" in the "Results" column is changed to "Done".
(3) Check all sensors and click the "Quit sensors check" button if the check results are
normal. If not, click the "Sensor test NG" button. Then, finish the inspection.
Cover sensor arm L
(Cover sensor 1)
Click if the sensors are normal.
"Undo" is chan g ed to "Done" after checkin g each sensor.
Fig. 12 Screen when checking the cover sensors and media sensors
Cover sensor arm R
(Cover sensor 0)
Media sensor ASSY
(Media sensor 0~5)
11
Media sensor ASSY
Click if any of the sensors
does not work correctl y .
"on" or "off" is displayed
according to the sensor condition.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents