Scale parameters and functions
8.3 DR 3 calibration parameters
Variable
Note
Reserve
Reserve
Reserve
Reserve
Minimum
Maximum factor for minimizing
display size
the SecureDisplay. Value must
[%]
not be smaller than the smallest
(Page 76)
value defined in the DisplayCali
file.
Reserve 4
Reserve
Parameter for calculation of calibration points with theoretical calibration
1)
8.3.2
Scale name
You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
The scale name cannot be changed after official verification.
8.3.3
Unit of weight
A string with up to four digits can be specified as the unit of weight, e.g.: t, kg, lbs. The
defined unit of weight applies to all weight specifications. Entries are not be converted if the
unit of weight has changed. Entries must be left-aligned.
8.3.4
Gross identifier
The gross identifier specifies the letter, B (for brutto) or G (for gross), to be used in the
display for gross weights.
8.3.5
Code for regulations
Trade scales requiring official calibration are subject to certain restrictions. The restrictions in
accordance with the OIML directive are activated by entering "1" for OIML R76. Enter "0" to
deactivate the restrictions (function available soon).
68
Type
Length
Read/write
(bytes)
protection
UBYTE[2]
2
rw
CHAR[20]
20
rw
USHORT
2
rwP
FLOAT
4
rw
Default
Min.
Max.
0
-
-
0
-
-
0
-
-
0
-
-
Manual, 07/2014, A5E31238908A-02
Modbus
registers
1082
1083
1093
1094
SIWAREX WP231