Dr 34 Ascii Main Display Value; Overview - Siemens SIWAREX WP231 Manual

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

8.22

DR 34 ASCII main display value

8.22.1

Overview

The ASCII weight corresponds to the value on the main display of the scales and can be
used for a supplementary display or operating display as well as the legal trade main display.
Reading of the current weight for legal trade use is only possible with the special
SecureDisplay software.
Table 8- 23
Assignment of data record 34
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application
the DR belongs to
Version iden-
Information about current data
tifier
record version
ASCII display
Maximum length and actual length
string header
of string
Content of
For legal trade display of weight
main display
with increased resolution, ... (see
as ASCII
below)
string
(Page 125)
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
Type
Length
Rw
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
UBYTE[2]
2
r
CHAR[16]
16
r
Scale parameters and functions
8.22 DR 34 ASCII main display value
Default
Min.
Max.
34
-
-
26
-
-
101
-
-
1
1
65635
16.2
-
-
" "
-
-
Modbus
registers
4000
4001
4002
4003
4004
4005
123