Operation requiring verification

12.1

Preparing for verification

12.1.1

Calibration set

The calibration set (available as Accessories (Page 175)) with the following contents is
available for operation requiring verification:
● SecureDisplay software for legal trade display of weight
● Ready-to-use project for TIA portal and TP 700 Comfort operator panel
● Manual
● Information on use of the module in operation requiring verification
● EC construction license for the module
● Test certificates for the displays
● Calibration plate for covering the connection terminals
● Templates for ID labels
● Tags for ID labels
● Self-adhesive markers "M" (green and red)
You can prepare the scale verification using the calibration set.
12.1.2

Scale design

If you wish to use the scale in operation requiring verification, the design must correspond to
the conditions specified in the construction license. Therefore you should already take the
specifications of the construction license into account when configuring and designing the
scale.
12.1.3
Installation and parameterization of the main SecureDisplay for legal trade in
the HMI
The SIWAREX SecureDisplay software serves as the legal trade main display of the scale.
The software must be installed on the HMI prior to the verification.
The DisplayCali.xml file can be used to parameterize the selectable display sizes and
positions on the HMI. You can find a complete description of the software installation in the
information "SIWAREX SecureDisplay".