Effective tare weight - from specification 1, 2 or 3

Up to three tare weights can be specified in the DR 15 data record. You activate a specified
tare weight with a command (see commands 1013, 1014, 1015). From this point on, the
activated tare weight is factored into the weight calculations. The "Delete tare" command
deactivates the active tare weight. This does not delete the specification in data record DR
15.
8.6.2

Effective tare weight (semi-automatic)

The corresponding command (see command 1011) applies the current gross weight as the
active tare weight. From this point on, the activated tare weight is factored into the weight
calculations. The "Delete tare" command deactivates the active tare weight.
8.6.3

Zero by power-on (value when switching on)

If the automatic zero by power-on is configured, the scale is automatically set to "Zero" when
the power supply is switched on provided the gross weight is within the defined zero setting
limits. The current gross weight is saved as the zero by power-on weight. The zero by
power-on weight must be within the specified range (usually ± 10 %).
8.6.4

Zero weight (semi-automatic)

The zero weight command (see command 1001) entered by the user sets the current gross
weight to "Zero" provided it is within the defined zero setting limits. The current gross weight
is saved as the zero weight. The zeroing weight must be within the specified range (usually
+3 / -1 % of the set zero point).
8.6.5

Current zero tracking weight

The current zero tracking weight is recorded in this parameter if automatic zero tracking is
activated.
8.6.6

Dead load

The characteristic curve of the scales is determined during calibration. When there is no
load, the main display returns "0". The dead load is the weight of the empty scales, i.e. the
weight of the scales themselves.