Scale parameters and functions

8.8 DR 7 interface parameters

8.8
DR 7 interface parameters
Data record DR 7 contains the parameters for defining the properties of the available I/O
modules (digital inputs, digital outputs, analog output, serial ports).
If a port is not used, the default values can be retained.
Procedure
● Change the parameters if necessary
● Transfer the data record to the scales
Table 8- 5
Assignment of data record 7
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length infor-
mation
Application
Information about which
application the DR belongs
to
Version identifier Information about the current
data record version
Assignment for
Assignment for input 0:
digital input 0, 1,
Code 0: No command as-
2, 3 (Page 92)
signed
1 ... 32767: Command is
triggered at a rising edge (0-
>1 transition)
Assignment for input 1:
Code 0: No command as-
signed
1 ... 32767: Command is
triggered at a rising edge (0-
>1 transition)
Assignment for input 2:
Code 0: No command as-
signed
1 ... 32767: Command is
triggered at a rising edge (0-
>1 transition)
Assignment for input 3:
Code 0: No command as-
signed
1 ... 32767: Command is
triggered at a rising edge (0-
>1 transition)
Input filtering
0: 0.2 ms
(hardware set-
1: 0.2 ms
ting) (Page 92)
2: 0.4 ms
3: 0.8 ms
4: 1.6 ms
5: 3.2 ms
6: 6.4 ms
7: 12.8 ms
88
Type
Length
RW
(bytes)
USHORT 2
r
USHORT 2
r
USHORT 2
r
USHORT 2
r
USHORT 2
rw
USHORT 2
rw
USHORT 2
rw
USHORT 2
rw
USHORT 2
rw
Default
Min.
Max.
7
-
60
-
101
-
1
1
65635
0
0
1999
0
0
1999
0
0
1999
0
0
1999
5
0
7
Manual, 07/2014, A5E31238908A-02
Modbus
Register
-
1300
-
1301
-
1302
1303
1304
1305
1306
1307
1308
SIWAREX WP231