Heart Rate Board Replacement - Vision Fitness T60 Service Manual

Hide thumbs Also See for T60:
Table of Contents

Advertisement

7.14 HEART RATE BOARD REPLACEMENT

1) Turn off power and remove the power cord from the unit.
2) Remove the 4 screws holding the console faceplate to the frame (Figure A).
3) Pull up on the console faceplate to locate the heart rate board on the back of the faceplate (Figure B).
FIGURE A
4) Disconnect the wires from each side of the heart rate board (Figure C).
5) Remove the 2 screws holding the heart rate board to the console (Figure D) and remove the heart rate board.
FIGURE C
6) Reverse Steps 1-5 to install a new heart rate board.
7) Test the treadmill for function as outlined in Section 7.15.
CHAPTER 7: PART REPLACEMENT GUIDE
FIGURE B
FIGURE D