Heart-Rate-Control Function Does Not Work - Vision Fitness Vision Series Service Manual

Hide thumbs Also See for Vision Series:
Table of Contents

Advertisement

Heart-Rate-Control function does not work

Possible causes:
1. Transmitter does not contact with user's chest very well.
2. Transmitter(Polar-belt) is at low battery status.
3. Transmitter(Polar-belt) is damaged.
4. Heart-rate-control board is damaged.
5. PCB is damaged.
Fix:
1. Center the transmitter on your chest below the pectoral muscle(breast)
as shown, then check again.
2. Remove the battery cover of the transmitter. Replace a new battery and
check again.
Actually, as moisture may activate the transmitter, please dry
transmitter after use.
3. OR
Transmitter is damaged. Replace the Transmitter.
4. OR
Heart-rate-control board is damaged. Replace the HR-control
board.
5. OR
PCB is damaged. Replace the PCB.