Troubleshooting - Error 01A8 / 01Ad / 02B6 / 02B7 / 02B8; Troubleshooting - Error 01Ab - Vision Fitness T60 Service Manual

Hide thumbs Also See for T60:
Table of Contents

Advertisement

6.8 TROUBLESHOOTING - ERROR 01A8 / 01AD / 02B6 / 02B7 / 02B8

POSSIBLE CAUSES:
1) 01A8 - Main motor over current (7 Amps).
2) 01AD - Inner electron over temperature. Motor over loading.
3) 02B6 - Speed up is over current.
4) 02B7 - Speed down is over current.
5) 02B8 - Running status over current.
SOLUTION:
1) Check the condition of the belt and deck. Flip or replace the deck if needed.
2) Replace the MCB.

6.9 TROUBLESHOOTING - ERROR 01AB

POSSIBLE CAUSES:
1) 01AB - Inverter Error.
SOLUTION:
1) With error 01AB present, the MCB Fault LED should be lit. If so, replace the MCB.
2) If the MCB Fault LED is not lit, replace the UCB.
CHAPTER 6: TROUBLESHOOTING
ERROR 01A8 / 01AD / 02B6 / 02B7 / 02B8
ERROR 01AB