NETGEAR GC728X User Manual page 357

Insight managed 28-port gigabit ethernet smart cloud switch with 2 sfp 1g & 2 sfp+ 10g fiber ports
Table of Contents

Advertisement

Insight Managed 28-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP 1G & 2 SFP+ 10G Fiber Ports
4.
Enter the switch's password in the password field.
The default password is password. If you added the switch to a network on the Insight
app before and you did not yet change the password through the local browser interface,
enter your Insight network password.
The System Information page displays.
5.
Select Maintenance > Troubleshooting > Ping IPv6.
The Ping IPv6 page displays.
6.
From the Ping menu, select the type of ping:
Global. Pings a global IPv6 address.
Link Local. Pings a link-local IPv6 address over a specified interface. With this
selection, the Interface menu displays, and you must select the interface.
7.
In the IPv6 Address/Hostname field, enter the IPv6 address or host name of the station
that must be pinged.
The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx. The maximum number of
characters is 255.
8.
In the Count field, enter the number of echo requests that must be sent.
The range is 1 to 15. The default value is 3.
9.
In the Interval field, enter the time in seconds between ping packets.
The range is 1 to 60. The default value is 3.
10.
In the Datagram Size field, enter the datagram size.
The valid range is 0 to 13000. The default value is 0 bytes.
11.
From the Source menu, select the IP address or interface that must be used to send echo
request packets:
None. The source address of the ping packet is the address of the default egress
interface.
IPv6 Address. The source IP address that must be used when echo request packets
are sent. With this selection, the IPv6 Address field displays and you must enter the
IPv6 address that must be used as the source.
Interface. The interface that must be used when echo request packets are sent. With
this selection, the Interface menu displays and you must select an interface as the
source.
12.
Click the Apply button.
The specified address is pinged. The results are displayed below the configurable data in
the Results field.
Perform Maintenance Tasks
357

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc728xp

Table of Contents