Oki C810 Maintenance Manual page 186

Hide thumbs Also See for C810:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Confirmation Items
(7-1-4) Check of connections

S ignal cord for motor
Check to see if the FFC is properly plugged in
driver PCB, EXIT
the RELAY
Connector ⑧ of the PU PCB and the PUIF
sensor cord
connector ㉒ of the junction PCB (P6Y PCB).
Check to see if the cord is properly connected in
the junction PCB (P6Y PCB) and EXIT sensor.
Signal cord for motor
Check to see if the cords are caught under any
driver PCB, EXIT
other part, or have any peel-off of the covering
sensor cord
or any assembling problem.
(7-2) Paper exit jam occurs right after feeding paper
Confirmation Items
(7-2-1) Check of state of running route
Face-up stacker
Check to see if the cover is completely open or
cover
closed.
Duplex pull-in gate
Conduct the Motor and Clutch Test of the self-
diagnostic mode, and check to see if the Duplex
pull-in gate operates normally.
Make sure that it is duly on the exit side.

Rear panel
C heck to see if the rear panel is installed
properly, and if it is not obstructing the paper
running route.
Running route in
Check visually for any load that obstructs
delivery section
running of paper along the route of the delivery
section. Check to see if the delivery rollers are
stiff in rotating.
(7-2-2) Check of state of mechanical parts


S ensor lever of exit
C heck to see if the sensor lever demonstrates
sensor
any abnormal shape or motion.
44072903TH Rev.1
Confirmation Tasks
Action at NG
Correct the
connection
properly.
Replace the
connection
cord, or correct
the assembling
properly.
Confirmation Tasks
Action at NG
Eliminate imper-
fect opening or
closing of the
cover.
Replace the
duplex pull-in
gate or replace
the duplex so-
lenoid.

R edo the
installation of
the rear panel.
Modify the load
portion.

R eplace the
sensor lever
with a normal
one.
Confirmation Items
(7-2-3) Motor operation check
Fuser motor
(7-2-4) Check of connections
Fuser motor drive
cord
Fuser motor

(7-3) Paper exit jam occurs in a path route
Confirmation Items
(7-3-1) Check of operating state of motor
Fuser motor
7. TROUBLESHOOTING PROCEFRURES
Confirmation Tasks

C onduct the Motor and Clutch Test of the self-
diagnostic mode, and check to see if the fuser
motor operates normally.
Make this checking in the presence and
absence of a load.
Check the connected state of the cord.
Check visually for any incomplete connection or
skew
insertion of the DCHEAT connector ④ of the
PU PCB or any assembling problem of the cord.
Confirmation Tasks
Conduct the Motor and Clutch Test of the self-
diagnostic mode, and check to see if the fuser
motor operates normally.
Make this checking in the presence and
absence of a load.
Action at NG
Replace the
PU PCB, fuser
motor, or fuser
unit. To use a
new fuser unit
on a trial basis,
use FUSE
KEEP MODE
of the System
Maintenance
Menu.
Correct the
connection
properly.
Replace the
cord with a
normal one.
Replace the
fuser motor.
Action at NG
Replace the
PU PCB, fuser
motor, or fuser
unit. To use a
new fuser unit
on a trial basis,
use FUSE
KEEP MODE
of the System
Maintenance
Menu.
186 /