Oki C810 Maintenance Manual page 128

Hide thumbs Also See for C810:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
• When print is executed, the following message is displayed:
P=***
W=***
P
: Number of test-print pages (Unit: sheets)
W
: Print wait time (Unit: seconds)
• Pressing the MENU
key switches over the indication.
T=*** U=***[###]
H=***%L=***[###]
U
: *** = Measured value of upper heater temperature [Unit: ˚C]
[###] = Target temperature for print execution [Unit: ˚C]
L
: *** = Measured value of lower thermistor [Unit: ˚C]
[###] = AD value of lower thermistor reading [Unit: HEX]
T
: Measured value of environmental temperature [Unit: ˚C]
H
: Measured value of environmental humidity [Unit: %]
key switches over the indication.
• Pressing the MENU
KTR=*.** YTR=*.**
MTR=*.** CTR=*.**
YTR, MTR, CTR and KTR denote the transfer voltage set values of the
respective colors (Unit: KV).
• Pressing the MENU
key switches over the indication.
KR=*.** YR=*.**
MR=*.** CR=*.**
KR
: BLACK transfer roller resistance value [Unit: uA]
YR
: YELLOW transfer roller resistance value [Unit: uA]
MR : MAGENTA transfer roller resistance value [Unit: uA]
CR
: CYAN transfer roller resistance value [Unit: uA]
44072903TH Rev.1
• The above displays are switched to the following by pressing the MENU
ETMP=***UTMP=***
REG=****EXT=***
ETMP :
A parameter for correction of constant hopping motor speed
(an environmental temperature) (in decimal).
UTMP :
A parameter for correction of constant fuser motor speed
(a target fusing temperature) (in decimal).
REG
:
A hopping motor constant-speed timer value (a set input/output value)
(in hex).
EXT
:
A fuser motor constant-speed timer value (a set input/output value)
(in hex).
• Pressing the MENU
key switches over the indication.
ID=****
KID, YID, MID and CID denote the constant-speed timer values of the
respective ID motors (I/ O set values) [Unit: HEX].
• Pressing the MENU
key switches over the indication.
BELT=****
FRM [***] ( xxx )
BELT : Constant speed timer value of belt motor (I/O set value) [Unit: HEX]
FRM : [***] = AD value of frame thermistor reading [Unit: HEX]
(xxx) = Frame temperature [Unit: ˚C]
• Pressing the MENU
key switches over the indication.
DB:k**y**m**c**
DB
: Development voltage setup table ID No. [Unit: HEX]
5. MENTENANCE MENUS
key.
128 /