Oki C810 Maintenance Manual page 150

Hide thumbs Also See for C810:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
LCD
Ready
Attention
means no display in
LED
upper line.
FLASH FORMAT
Off
PROGRAM UPDATE
Off
MODE
WAIT A MOMENT
Off
DATA RECEIVE
WAIT A MOMENT
Off
DATA RECEIVED OK
CHECK DATA
Off
REC DATA ERROR
<%DLCODE%>
WAIT A MOMENT
Off
DATA WRITING
POWER OFF/ON
Off
DATA WRITTEN OK
44072903TH Rev.1
Description
LED
Off
Displays that Flash memory is being formatted.
It is displayed it when Resident/Option
Flash memory not fomented are detected, or
"MAINTENANCE MENU"
- "FLASH FORMAT" of a system maintenance
menu is performed.
The function mentioned above is secret to
users.
Therefore, this status does not occur in a user
environment.
Off
Displays that a printer is a special mode
to conduct the update of the NIC program
(Controller firmware).
This mode starts by turning on power with
pressing Online switch.
Blink
Displays that the NIC program data to update is
being received.
Off
Displays that the NIC program data to update
has been received.
On
Displays that an error takes place while a
program data to update is being received.
%DLCODE%
1: Size Error
2: Check SUM Error
3: Printer Model No. Error
4: Module I/F Version Error
5: FAT Version Error  
Blink
Displays that the NIC program data to
update is being written.
Off
Displays that the NIC program data to
update has been written.
LCD
Ready
Attention
means no display in
LED
LED
upper line.
CHECK DATA
Off
On
DATA WRITE ERROR
<%DLCODE%>
LOADER VERSION
Off
Off
XX ・ XX
COMMUNICATION
Off
Off
ERROR
STATUS MODE
Off
Off
7. TROUBLESHOOTING PROCEFRURES
Description
Displays that an error takes place while the NIC
program data to update is being written.
%DLCODE%
1: Memory alloc Error
2: Download File Error
3: Device Free space acquirement Error
4: Device Free area Shortage Error
5: File Write Error
6: CU-F/W Mismatch Error
It is shown that PU firmware has booted in
Loader mode.
This status may occur also in a user
environment. When
it occurs, the maintenance by a maintenance
member is required (equivalent to S/C).
Displays that communication to PU firmware
failed.
This status may occur also in a user
environment. When it occurs, the maintenance
by a maintenance member is required
(equivalent to S/C).
Displays that normal Online mode starts.
Data (Job) from an external portion is
processed even though an error takes place
after Online (ready) state once this mode
starts.
Displays Error or Warning on a panel.
If a power supply is turned on pressing a
<Enter>+<Back>+<Menu
> switch, it will
enter into this mode.
This function is secret to users. Therefore, this
status does not occur in a user environment.