Oki C810 Maintenance Manual page 172

Hide thumbs Also See for C810:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Confirmation Items
(2-2-4) Check of laying of cords
Laying of peripheral
Check to see if the peripheral cords of the
cords around each
FAN are laid so poorly that the FAN blades are
cooling FAN
touching the cords.
If the cords are laid improperly, "cluck, cluck"
will be heard.
(2-2-5) Check of installed state of mechanical parts
Check the installed
Remove the PCBs and check visually the
state of the sill
installed state of the sill plates.
plates under the CU
and PU PCBs.
(2-3) Abnormal odor
Confirmation Items
(2-3-1) Location of source of foul smell
Fuser unit
Take out the fuser unit, and check for the smell.
Low voltage power
Take out the lower-voltage power supply unit,
supply unit
and check for the smell.
(2-3-2) Check of state of Fuser unit
Life count of fuser
Check the life count of the fuser unit in the self-
unit
diagnostic mode.
Check for foreign
Check for any foreign matter trapped in the
matter in fuser unit
fuser unit, such as a paper chip.
44072903TH Rev.1
Confirmation Tasks
Action at NG

Correct the
laying of cords.

If the sill plates
are not hooked
in the prescribed
positions,
correct their
installation.
Confirmation Tasks
Action at NG
Conduct (2-3-2).
Replace the low
voltage power
supply unit.
If the unit is
like-new, it
necessarily
emits some foul
smell.
Remove the
foreign matter.
(2-4) Slow starting time
Confirmation Items
(2-4-1) Check of fuser unit
Halogen lamp
Check the label on the back of the fuser unit to
make sure that the voltage of the lamp is 100V.
7. TROUBLESHOOTING PROCEFRURES
Confirmation Tasks
Action at NG
Replace the
fuser unit.
172 /