CableIQ Qualification Tester
Users Manual
Crossed wires.
Detection requires a far-end adapter.
If the tester detects multiple faults that produce the warning symbol (
priority fault is displayed. The priority for these faults (highest to lowest) is split pair, bridge tap,
and A/B crossover cable.
26
avv20.bmp
Split pair. Continuity from end to end is correct, but is made with the
wrong wires.
Cables with untwisted pairs, such as telephone cords,
typically show split pairs due to excessive crosstalk. Because
this crosstalk does not affect voice signals, the split pair
warning does not cause a Telco wiremap test to fail.
Note
Figure 10. Typical Wiremap Screens (cont.)
Note
W
), only the highest-
avv19.eps
-continued-