Fluke MicroScanner 2 User Manual

Fluke MicroScanner 2 User Manual

Cable verifier
Table of Contents

Advertisement

2
TM
MicroScanner
Cable Verifier
Users Manual
January 2007, Rev. 2 8/2016
©2007, 2015, 2016 Fluke Corporation
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke MicroScanner 2

  • Page 1 MicroScanner Cable Verifier Users Manual January 2007, Rev. 2 8/2016 ©2007, 2015, 2016 Fluke Corporation All product names are trademarks of their respective companies.
  • Page 2 Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ..................................1 Registration ................................... 1 Contacting Fluke Networks ..............................2 Symbols ....................................2  Safety Information ................................. 3 MicroScanner Features ................................ 6 Display Features ..................................8 Auto Shutoff ..................................9 Changing the Length Units ..............................9 Using the Wiremap Adapter and Remote ID Locators .......................
  • Page 4 MicroScanner Cable Verifier Users Manual Crossed Wires ................................13 Crossed Pairs ................................14 Split Pair .................................. 15 Telephone Voltages Detected ..........................16 Bridge Tap Detected ............................... 17 Ethernet Port Detected ............................18 Viewing Individual Results ............................. 20 Using Multiple Remote ID Locators ..........................22 Connecting to Telephone Networks Wired in Star Topologies ...................
  • Page 5 Table of Contents Using the IntelliTone Cable Map Function (optional IP200 probe required) ..............36 Calibrating Length Measurements ............................38 Setting the NVP to a Specified Value ........................... 38 Determining a Cable’s Actual NVP ..........................38 Maintenance ..................................39 Cleaning ..................................40 Battery Life, Status, and Replacement .........................
  • Page 6 MicroScanner Cable Verifier Users Manual Crossed Pairs ................................... 47 Short ....................................48 Index ...................................... 49...
  • Page 7 List of Figures Figure Title Page High Voltage Display Example ........................5 MicroScanner Features ..........................6 Display Features ............................. 8 Connecting a Remote ID Locator in a Confined Area or to an RJ11 Jack........... 10 Connecting to Twisted Pair Network Cabling ....................11 Open on Twisted Pair Cabling ........................
  • Page 8 MicroScanner Cable Verifier Users Manual Using Multiple Remote ID Locators....................... 23 Connecting to a Telephone Network Wired in a Star Topology ..............25 Connecting to a Telephone Network Wired in a Bus Topology..............27 Connecting to Coaxial Cabling ........................28 Coaxial Results ..............................
  • Page 9: Introduction

    To register,  Displays wiremap, cable length, proportional distance fill out the online registration form on the Fluke Networks to opens, and the remote ID number all on one screen. website at www.flukenetworks.com/registration. ...
  • Page 10: Contacting Fluke Networks

    MicroScanner Cable Verifier Users Manual Contacting Fluke Networks Table 1. Symbols www.flukenetworks.com Warning or Caution: risk of damage or  support@flukenetworks.com destruction to equipment or software. See explanations in the manual. +1-425-446-5500  Australia: 61 (2) 8850-3333 or 61 (3) 9329 0244 On the tester’s display this symbol indicates a...
  • Page 11: Safety Information

     Use only replacement parts that are approved by notice of it. This equipment is intended for Fluke Networks. use in business environments and is not to be used in homes. ...
  • Page 12 MicroScanner Cable Verifier Users Manual    voltage polarities ( ) when it detects high Batteries contain hazardous chemicals that can    voltage. Disconnect the tester if cause burns or explode. If exposure to chemicals appear. Figures 1 and 11 show examples of this occurs, clean with water and get medical aid.
  • Page 13: High Voltage Display Example

    Safety Information  Do not disassemble or crush battery cells and battery packs.  Do not put battery cells and battery packs near Positive heat or fire. Do not put in sunlight.  Do not operate the Product with covers removed or the case open.
  • Page 14: Microscanner 2 Features

    MicroScanner Cable Verifier Users Manual MicroScanner Features egk01.eps Figure 2. MicroScanner Features...
  • Page 15 MicroScanner Features   On/off key. LCD display with backlight.     F-connector for connecting to 75  coaxial cable. : Navigates through screens and changes settings. In toner mode, these keys cycle through the  Modular jack for connecting to telephone and twisted IntelliTone and analog toner songs.
  • Page 16: Display Features

    MicroScanner Cable Verifier Users Manual  Tester icon Display Features  Detail screen indicator. See page 20.   Indicates which port is active, the RJ45 port ( ) or the  coaxial port (  Tone mode indicator. See page 32. ...
  • Page 17: Auto Shutoff

    Auto Shutoff  Wiremap diagram. For opens, the number of segments Changing the Length Units lit for the wire pair indicates the approximate distance   Hold down while turning on the tester. to the fault. The rightmost segments indicate the shield.
  • Page 18: Using The Wiremap Adapter And Remote Id Locators

    MicroScanner Cable Verifier Users Manual Using the Wiremap Adapter and Remote ID Locators Terminating twisted pair cabling with the standard Universal adapter wiremap adapter or optional remote ID locators lets the (8-pin and 4-pin) tester detect all types of wiremap faults. Without this termination, the tester cannot detect crossed wires or crossed pairs.
  • Page 19: Testing Twisted Pair Cabling

    Testing Twisted Pair Cabling Testing Twisted Pair Cabling Turn on the tester.  If the tester is already on and in coaxial test mode (   press to switch to twisted pair test mode ( Patch panel Connect the tester and wiremap adapter or ID locator to the cabling as shown in Figures 5 through 17.
  • Page 20: Twisted Pair Test Results

    MicroScanner Cable Verifier Users Manual Twisted Pair Test Results The following figures show typical test results for twisted pair cabling. Open on Twisted Pair Cabling Figure 6 shows an open on wire 4. Notes If only one wire in a pair is open and a wiremap adapter or remote ID locator is not connected, both wires are shown as open.
  • Page 21: Short On Twisted Pair Cabling

    Testing Twisted Pair Cabling Short on Twisted Pair Cabling Crossed Wires Figure 7 shows a short between wires 5 and 6. The shorted Figure 8 shows that wires 3 and 4 are crossed. The the pin wires flash to indicate the fault. The cable length is 75.4 m. numbers flash to indicate the fault.
  • Page 22: Crossed Pairs

    MicroScanner Cable Verifier Users Manual Crossed Pairs Figure 9 shows that pairs 1,2 and 3,6 are crossed. The pin numbers flash to indicate the fault. This crossed pair is likely caused by mixing 568A and 568B cabling. Detection of crossed pairs requires a far-end adapter. egk09.eps Figure 9.
  • Page 23: Split Pair

    Testing Twisted Pair Cabling Split Pair Figure 10 shows a split pair on 3,6 and 4,5. The split pair flashes to indicate the fault. The cable length is 75.4 m. In a split pair, continuity from end to end is correct, but is made with wires from different pairs.
  • Page 24: Telephone Voltages Detected

    MicroScanner Cable Verifier Users Manual Telephone Voltages Detected Telephone Figure 11 shows that telephone voltage is detected on pair voltage icon 4,5. Length is not shown because the voltage interferes with length measurements. Positive wire (tip)   Warning Negative The tester is not intended to be connected to wire (ring) active telephone inputs, systems, or equipment,...
  • Page 25: Bridge Tap Detected

    Testing Twisted Pair Cabling Bridge Tap Detected Figure 12 shows a bridge tap detected at about 53.2 m. Only the first bridge tap detected is reported. The distance to a bridge tap is approximate because multiple reflections from the bridge tap interfere with length measurements. Note Bridge taps more than 328 ft (100 m) from the tester or taps less than 16 ft (5 m) long may not be...
  • Page 26: Ethernet Port Detected

    MicroScanner Cable Verifier Users Manual  Cable length. Dashes are shown if the tester cannot Ethernet Port Detected measure the length. This can occur if the port does not The tester can detect active and inactive Ethernet ports, as produce reflections. shown in Figure 13.
  • Page 27: Ethernet Port Detected

    Testing Twisted Pair Cabling Active Ethernet port Inactive Ethernet port egk13.eps Figure 13. Ethernet Port Detected...
  • Page 28: Viewing Individual Results

    MicroScanner Cable Verifier Users Manual  Short on pair 1,2 at 29.8 m. Viewing Individual Results   To see individual results for each wire pair, use ; to Notes move among the screens. On the individual results screens, shorts are shown only when they are between wires in a pair.
  • Page 29: Results Screens For Individual Wire Pairs

    Testing Twisted Pair Cabling egk14.eps Figure 14. Results Screens for Individual Wire Pairs...
  • Page 30: Using Multiple Remote Id Locators

    MicroScanner Cable Verifier Users Manual  Using Multiple Remote ID Locators Caution Using multiple remote ID locators helps you identify Do not use multiple far end adapters in star or multiple network connections at a patch panel, as shown in bus topologies.
  • Page 31: Using Multiple Remote Id Locators

    Testing Twisted Pair Cabling Patch panel Locator # 2 Locator # 3 Remote ID locators connected to wall outlets Locator # 4 Locator # 5 egk04.eps Figure 15. Using Multiple Remote ID Locators...
  • Page 32: Connecting To Telephone Networks Wired In Star Topologies

    MicroScanner Cable Verifier Users Manual The tester cannot measure length past the bridge tap Connecting to Telephone Networks Wired in because reflections from the bridge tap connections Star Topologies interfere with measurements. Telephone cables wired in a star topology (Figure 16) are connected together at a bridge tap at the distribution If you connect the tester to the bridge tap, the tester center.
  • Page 33: Connecting To A Telephone Network Wired In A Star Topology

    Testing Twisted Pair Cabling Distribution center Common connection RJ11 patch Wall to bridge tap cord outlets RJ11 patch cord Wiremap adapter Note: For a correct length reading, connect the tester and wiremap adapter as shown. See “Connecting to Star Topologies” for details. egk16.eps Figure 16.
  • Page 34: Connecting To Telephone Networks Wired In Bus Topologies

    MicroScanner Cable Verifier Users Manual If you are unsure which outlet is the last in the bus, do the Connecting to Telephone Networks Wired in Bus following: Topologies Telephone cables wired in a bus topology (Figure 17) Connect the wiremap adapter or ID locator to the connect the wall outlets in series.
  • Page 35: Connecting To A Telephone Network Wired In A Bus Topology

    Testing Twisted Pair Cabling Distribution center Connection to bus Wall outlets RJ11 patch cord RJ11 patch cord Wiremap adapter Note: Locations of the tester and wiremap adapter may be swapped. egk17.eps Figure 17. Connecting to a Telephone Network Wired in a Bus Topology...
  • Page 36: Testing Coaxial Cabling

    MicroScanner Cable Verifier Users Manual Testing Coaxial Cabling  Turn on the tester; then press to switch to coaxial Connection to  test mode ( service Connect the tester and wiremap adapter or ID locator to the cabling as shown in Figure 18. For cabling not terminated with an F-connector, use an adapter or hybrid patch cord to connect to the cabling.
  • Page 37: Coaxial Results

    Testing Coaxial Cabling Coaxial Results Open on Coaxial Cabling Figure 20 shows an open 12.1 m from the tester. Figure 19 shows a good coaxial cable 38.4 m long and terminated with remote ID number 3. egk21.eps Figure 20. Open on Coaxial Cabling egk20.eps Figure 19.
  • Page 38: Short On Coaxial Cabling

    MicroScanner Cable Verifier Users Manual Short on Coaxial Cabling Unknown Termination on Coaxial Cabling Figure 21 shows a short 12.1 m from the tester. Figure 22 shows a cable connected to a device at the far end, such as a television, CATV service, VCR, DVD player, satellite dish, splitter, or antenna.
  • Page 39: Detecting Power Over Ethernet

    Detecting Power Over Ethernet Detecting Power Over Ethernet The tester can detect PoE voltage from 802.3af sources.  To select PoE mode, press until appears on the  display, as shown in Figure 23 ( In PoE mode, the tester solicits PoE power on pairs 1,2-3,6 and 4,5-7,8.
  • Page 40: Using The Toner

    Refer to Figures 24 and 25. locate cables in bundles, at patch panels, or behind walls. Connect the tester to the cable. Use the tester’s IntelliTone mode with an optional Fluke ™ Networks IP100 or IP200 tone probe. The digital IntelliTone ...
  • Page 41: Intellitone Toner Mode Display

    Using the Toner Notes If you cannot locate the IntelliTone signal on 2-conductor cables, the cable may be shorted. Use the tester to check for shorts. See pages 11 and 13.  Turn the probe’s rotary switch to (isolate). Use the probe to isolate the tone source in the cable bundle or at the patch panel.
  • Page 42: Using The Toner In Intellitone Mode

    MicroScanner Cable Verifier Users Manual Locating Cables Isolating Cables Wall outlet Volume control egk24.eps Figure 25. Using the Toner in IntelliTone Mode...
  • Page 43: Analog Toner Mode (Optional Tone Probe Required)

    Using the Toner Analog Toner Mode (optional tone probe required) Refer to Figure 26. Connect the tester to the cable.  Press to select twisted pair or coaxial cable.    Press until appears on the display ( ); then ...
  • Page 44: Using The Smarttone Function

    MicroScanner Cable Verifier Users Manual Using the SmartTone Function Using the IntelliTone Cable Map Function (optional IP200 probe required) Use the SmartTone function when you have trouble ™ locating a cable. This function changes the toner’s song The tester’s IntelliTone function works with an optional when you short a wire pair in the cable connected to the IP200 probe’s cable map function to verify wiring at the far tester.
  • Page 45: Using The Toner With The Ip200 Intellitone Cable Map Function

    Using the IntelliTone Cable Map Function (optional IP200 probe required) Note Normally, the probe’s SYNC LED lights to indicate reception of the IntelliTone signal. You may change the LED’s function to indicate shield continuity. See the probe’s documentation for details. LEDs show the wiremap.
  • Page 46: Calibrating Length Measurements

    MicroScanner Cable Verifier Users Manual Calibrating Length Measurements Setting the NVP to a Specified Value To enter the NVP value specified by the manufacturer: The tester uses an NVP value (nominal velocity of propagation) and the signal delay through the cable to ...
  • Page 47: Maintenance

     Use only specified replacement parts for user- To save the setting and exit NVP mode, turn the tester replaceable items. off then on again.  Use only Fluke Networks authorized service centers.
  • Page 48: Cleaning

    MicroScanner Cable Verifier Users Manual You can use the following types of AA (IEC LR6) batteries in Cleaning the tester: Clean the display with glass cleaner and a soft, lint-free cloth. Clean the case with a soft cloth dampened with ...
  • Page 49: Checking The Tester's Version And Serial Number

      to scroll through the screens: If Table 2 does not help you solve a problem with the tester, contact Fluke Networks for additional help. If possible, have     : Software version the tester’s version and serial number.
  • Page 50: Options And Accessories

    MicroScanner Cable Verifier Users Manual Options and Accessories See Table 3. For the latest list of options and accessories visit the Fluke Networks website at www.flukenetworks.com. Table 3. Options and Accessories Option or Accessory Fluke Networks Model Number Remote ID Locator Kit, numbers 2-7...
  • Page 51: Specifications

    Specifications Specifications Specifications apply at 23 C (73 F), unless otherwise noted. Environmental Specifications 32 °F to 113 °F (0 C to 45 Operating temperature -4 °F to +140 °F (-20 C to +60 Storage temperature 90 % (50 °F to 95 °F; 10 C to 35 Operating relative humidity 75 % (95 °F to 113 °F;...
  • Page 52: General Specifications

    MicroScanner Cable Verifier Users Manual General Specifications Shielded 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs. Test connectors F-connector for coaxial cable. Battery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries Power Battery life: 20 hours of typical use Other compatible battery types: 2 AA photo lithium, NIMH, NICAD 3 in x 6.4”...
  • Page 53: Performance Specifications

    The wiremap is drawn with proportional length to visually indicate the approximate location of faults. Detects the advertised speed of 802.3 Ethernet ports. Port detection Supports toning and cable mapping with a Fluke Networks digital IntelliTone probe. ™ Tone generator Generates four tones compatible with typical analog probes.
  • Page 54: Regulatory Information

    MicroScanner Cable Verifier Users Manual Regulatory Information This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15, Subpart J of the FCC rules, which are designed to provide reasonable protection against such interference...
  • Page 55: Appendix A: Diagnosing Wiremap Faults

    Appendix A: Diagnosing Wiremap Faults Appendix A lists the typical causes of wiremap failures. Split Pair Wires connected to wrong pins at connector or punchdown Open block.  Wires connected to wrong pins at connector or punchdown blocks Reversed Pairs ...
  • Page 56: Short

    MicroScanner Cable Verifier Users Manual Short  Damaged connector  Damaged cable  Conductive material stuck between pins at connector.  Improper connector termination  Wrong application for cable...
  • Page 57: Index

    Index cable tests Symbols coaxial cabling, 28 "?" on coaxial screen, 30 twisted pair, 11 cleaning, 40 –A– coaxial accessories, 42 connections, 28 analog toner, 35 open, 29, 30 auto shutoff, 9 short, 30 –B– unknown termination, 30 connections batteries, 40 coaxial, 28 bridge tap, 17 twisted pair, 11...
  • Page 58 MicroScanner Cable Verifier Users Manual customer support –K– contacting Fluke Networks, 2 keys, 7 problem with the tester, 41 –L– –E– length calibration, 38 Ethernet port detected, 18 –M– –F– maintenance, 39 Fluke Networks, 2 –N– –H– NVP, 38 help contacting Fluke Networks, 2 –O–...
  • Page 59 Index testing –R– coaxial cabling, 28 registration, 1 twisted pair cabling, 11 remote ID locator, 10, 22 toner, 32 replacement parts, 42 analog mode, 35 RJ11 jack, 10 IntelliTone mode, 32 SmartTone function, 35, 36 –S– troubleshooting safety information, 3, 39 cabling faults, 47 serial number, 41 the tester, 41...
  • Page 60 MicroScanner Cable Verifier Users Manual split pair, 15 telephone voltages, 16 –U– universal adapter, 10 –V– version information, 41 voltage detection, 5, 16 –W– wiremap adapter, 10...

Table of Contents