Trim and Tilt
Check reservoir fluid level every three years or
every 300 operating hours.
System capacity is approximately 21 fl. oz. (620
•
ml).
Tilt the outboard and engage the tilt support.
•
1
1. Tilt support bracket
Remove the fill plug.
•
•
Three Ram System–Add Power Trim/Tilt Fluid
or GM Dexron II, as needed, to bring level to the
bottom of the fill plug threads.
1
Three Ram Trim System
1. Fill cap
Install the fill plug and tighten to a torque of 45
•
to 55 in. lbs. (5 to 6 N·m).
Disengage tilt support.
•
Cycle the unit at least five complete cycles to
•
002279
purge all air from the system. When cycling the
unit, hold the trim switch ON an additional 5 to
10 seconds after the unit reaches the end of its
travel before activating the switch in the oppo-
site direction.
Correct fluid level must be maintained to
ensure operation of the impact protection
built into the unit.
MAINTENANCE
LUBRICATION
WARNING
3
004277
81