Software Method; Pyrometer Method - BRP E200HSLSEA Service Manual

Evinture e-tec. 200 hp,225 hp,250 hp,300 hp, 90 grd. v6
Table of Contents

Advertisement

Software Method

Use Evinrude Diagnostics software to read tem-
perature displays.
Engine Monitor Screen
Typical temperature displays at IDLE speed
should be 160°F ± 10°F (71°C ± 6°C)
Operating temperature must not exceed 194°F
(90°C).

Pyrometer Method

Use a Temperature Gun, P/N 772018, or a digital
pyrometer to measure the outboard's operating
temperature.
Measure temperature at the top of cylinder block,
next to the thermostat housing and cylinder head.
Check temperature on both sides of powerhead.
1. Top of cylinder block (starboard side)
ENGINE TEMPERATURE CHECK
Typical temperatures observed at IDLE speed
with pyrometer should be 143°F ± 15°F (62°C ±
8°C)
IMPORTANT:
ings with a digital pyrometer, coat the probe loca-
tion with Thermal Joint Compound, P/N 322170.
Idle Operating Temperature
Troubleshooting (Below Range)
If engine IDLE temperature is below operating
range 160°F ± 10°F (71°C ± 6°C), check thermo-
stat and pressure relief valve operation.
Pressure Relief Valve
The pressure relief valve should be closed at
IDLE speed. Water should not flow past the
plunger and seal.
006958
Pressure Relief Valve
If IDLE temperature increases to specific operat-
ing range, pressure relief valve and thermostats
are functioning properly.
1
004339
COOLING SYSTEM
If you get low or inaccurate read-
Plunger
Seal
DRC8113
10
213

Hide quick links: