Operating Temperature - BRP E200HSLSEA Service Manual

Evinture e-tec. 200 hp,225 hp,250 hp,300 hp, 90 grd. v6
Table of Contents

Advertisement

Tachometer Pulse Setting
Confirm accuracy of tachometer reading.
Adjust dial on back of tachometer to required
setting (the outboard should not be running).
Outboard Model
40–300 HP
Water Pump Overboard Indicator
A steady stream of water should flow from the
overboard indicator.
1. Water pump overboard indicator
Tachometer Setting
6 Pulse or 12 Pole
1
DRC4952
INSTALLATION AND PREDELIVERY

Operating Temperature

An outboard run at idle speed should achieve a
temperature based on the engine's thermostatic
control. In general, the powerhead temperature
should reach at least 104°F (40°C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature. Refer to specific SERVICE
SPECIFICATIONS on p. 10.
Idle Speed
Make sure the outboard idles within the specified
idle RPM range. If the outboard is run on a flush-
ing device, the idle speed and quality may not be
representative of actual in water use.
Break-In
When the outboard is delivered, refer the cus-
tomer to the break-in information in the Opera-
tor's Guide.
The Engine Management Module (EMM) auto-
matically supplies extra oil to the engine during
the first two hours of operation, above 2000 RPM.
Use the diagnostics software to confirm that the
break-in program has been started. Refer to Oil
Control Settings on p. 106.
RUNNING CHECKS
65
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents