Starter Removal; Starter Disassembly - BRP E200HSLSEA Service Manual

Evinture e-tec. 200 hp,225 hp,250 hp,300 hp, 90 grd. v6
Table of Contents

Advertisement

ELECTRIC STARTER
SERVICING

Starter Removal

Do not clean the starter drive
IMPORTANT:
while the starter motor and drive are installed on
the powerhead. The cleaning agent could drain
into the starter motor, washing dirt from the drive
into the starter bearings and commutator.
Disconnect the battery cables at the battery.
Remove the starter positive (+) cable from post on
starter.
Remove the four frame and bracket mounting
screws. Lift and remove the starter.
Loosen the two nuts used to fasten the starter
bracket. Remove the nuts and bracket.
ELECTRIC STARTER SERVICING
Remove the screws, lock washers, and pinion
housing.

Starter Disassembly

Lift and remove the wave washer and bushing.
004181
Place an appropriate-sized deep socket on the
spacer.
30374
ELECTRICAL AND IGNITION
30373
7
30372
153