SYSTEM ANALYSIS

DIAGNOSTIC PROCEDURES

DIAGNOSTIC
PROCEDURES
Visual Inspections
Inspect wiring and electrical connections. Disas-
semble and clean all corroded connections.
Replace damaged wiring, connectors, or termi-
nals. Repair any shorted electrical circuits.
Refer to ELECTRICAL HARNESS CONNEC-
TIONS on p. 130.
Refer to WIRING DIAGRAM at the back of this
manual.
Refer to CONNECTOR SERVICING on p. 160.
Make sure all ground connections are clean and
tight. Refer to GROUND CIRCUITS on p. 132.
2
1. Main engine harness ground
2. Ground stud (battery)
Inspect spark plugs for wear, oil fowling, or dam-
age. A rich or lean running condition or evidence
of internal engine damage could be identified by
the appearance of the spark plugs.
Check the fuse and the emergency stop switch
lanyard.
112
Diagnostic Software Inspections
Before running the outboard, use Evinrude Diag-
nostics software to review historical information
stored in the EMM.
Check the Hard Faults and Stored Faults screens
for current service codes. Correct any problems
and clear the codes before further troubleshoot-
ing. Refer to Stored Service Codes (Faults) on
p. 104.
On some models, the stored code screen will dis-
play detailed information about the operating con-
ditions of the engine at the time the code was set.
1
1
Stored Faults Review Screen
1. Detailed information
005315
Review information about how the outboard has
been operated using the Profiles screens.
RPM Profile
007136
007199