Event name
PLC Function Processing Error
Meaning
A fatal error was detected in the PLC Function Module.
Source
PLC Function Module
Error attributes
Level
Effects
User program
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
An error occurred in the software.
Attached
Attached information 1: System information
information
Attached Information 2: System information
Attached information 3: System information
Attached information 4: System information
Precautions/
None
Remarks
*1 Operation is the same as for a major fault level error. For details, refer to I/O Operation for Major Fault Level Controller
Errors on page 5-7.
Event name
PLC Function Processing Error
Meaning
A fatal error was detected in part of the PLC Function Module.
Source
PLC Function Module
Error attributes
Level
Effects
User program
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
An error occurred in the software.
Attached
Attached information 1: System information
information
Attached Information 2: System information
Attached information 3: System information
Attached information 4: System information
Precautions/
None
Remarks
NX-series CPU Unit Hardware User's Manual (W535)
Source details
Partial fault
Recovery
Stops.
Operation
Data type
---
Correction
Contact your OMRON representative.
Source details
Minor fault
Recovery
Continues.
Operation
Data type
---
Correction
Contact your OMRON representative.
5 Troubleshooting
Event code
40120000 hex
None
Detection
timing
Cycle the power
Log category
supply.
*1
Stops.
Name
---
Prevention
None
Event code
40130000 hex
None
Detection
timing
Cycle the power
Log category
supply or reset
the Controller.
Operation is not affected.
Name
---
Prevention
None
Continuously
System
5
Continuously
System
5 - 59