2. WIRING
2.6.3
How to set jumper blocks in the sensor adapters
MC-3000S
Set the jumper blocks on the MC-CS Board (24P0114) referring to the tables that fol-
low.
J19
(J20/J21 are not used)
Jumper block: Use the jumper block J19 to set the termination resistor on/off for the
MODBUS communication on the connector J1. For the first and last sensor adapter in
a series, their termination resistors must be set to ON. Use the MC-CS Board with the
default setting because it becomes the "first" adapter in a series.
Jumper block J19
1-2
2-3
1-2
2-3
Set the jumper blocks J14 through J17 to turn the termination resistors on connectors
J4 through J7, respectively.
2-44
J14 J22 J23 J15 J16 J17
J20 J21
MC-CS Board (24P0114)
SHORT
Termination resistor: ON (default setting)
OPEN
OPEN
Termination resistor: OFF
SHORT
(J22/J23 are not used)
Connector J1
S2
(Not Used)

Hide quick links: