Furuno FAR-3210 Installation Manual page 61

Chart radar
Hide thumbs Also See for FAR-3210:
Table of Contents

Advertisement

Connections
Unfasten four screws to remove the cover. Pass the cables through the clamps and
attach the cables to respective connectors. The shield (or drain wire) must lie in (con-
nected to) the clamp.
Note: Be sure each cable shield lies in the cable clamp.
How to set NC/NO output (J2)
The POWER FAIL signal on the connector J2 can be set to NC (normal close) output
or NO (normal open) output as shown in the table below.
Pin #
Signal name
1
24V_IN
2
24V_GND
3
PWR_FAIL_A
4
PWR_FAIL_COM
5
PWR_FAIL_B
J9
J9
J7
J7
J8
J8
J5
J5
J6
J4
J1
J1
J2
J2
TTYCS-4/
TTYCSLA-4
TTYCSLA-4
MC1.5-W-L cable
MC1.5-W-L cable
DPYC1.5
DPYC1.5
Connector J2
In/Out
-
24 VDC
-
GND (24 VDC)
Out
Power fail output
Out
Power fail output
Out
Power fail output
For TTYCSLA cables, attach a shrinking
tube (local supply), to drain wire, then use
these crimp-on lugs and screws
to connect the drain wire here.
FR-FTPC-CY cable
FR-FTPC-CY cable
IV-1.25sq. (Local supply)
IV-1.25sq. (Local supply)
TTYCS-1Q/
TTYCS-1Q/
TTYCSLA-1Q
TTYCSLA-1Q
Remarks
NO
DPYC-1.5
TTYCS(LA)-1
No connection
2. WIRING
NC
No connection
TTYCS(LA)-1
2-33