Unit Control Parameters - Alvarion BreezeACCESS VL 5.4 System Manual

Breezeaccess vl series
Table of Contents

Advertisement

D-4
MIB Parameter
*MaxPowerOutput
(*SysInfo 12)
*CurrentNumOfAssociations
(*SysInfo 13)
*UnitBootVersion
(*SysInfo 14)
*RadioBand
(*SysInfo 15)

Unit Control Parameters

MIB Parameter
*UnitControl
(breezeAccessVLMib 2)
*ResetUnit
(*UnitControl 1)
*SetDefaults
(*UnitControl 2)
*UnitName
(*UnitControl 3)
*FlashMemoryControl
(*UnitControl 4)
*TelnetLogoutTimer
(*UnitControl 5)
BreezeACCESS VL System Manual
Description
Applicable to AU and SU. Read-only:
The maximum output power in dBm to
the antenna port supported by the unit.
Applicable to AU only. Read-only. The
number of subscriber units currently
associated with the AU.
Applicable to AU and SU. Read-only:
The Boot software version.
Applicable to AU and SU. Read-only:
The radio band of the unit.
Description
Applicable to AU and SU. Resets
the unit and applies new parameter
values.
Applicable to AU and SU. Sets unit
configuration to Defaults values
after the next reset.
completeFactory: All parameters
revert to Factory Defaults values
partialFactory: All parameters
revert to Factory Defaults values,
except the parameters required for
maintaining wireless connectivity.
completeOperator: All parameters
revert to Operator Defaults values
partialOperator: All parameters
revert to Operator Defaults values,
except the parameters required for
maintaining wireless connectivity.
Applicable to AU and SU. The unit
name.
Applicable to AU and SU.
Reset And Boot From Shadow
Version: Activates the shadow
version.
Use Current Version After Reset:
The currently active version will
become the main version and will
be activated after next reset.
Applicable to AU and SU.
Time-out of management via
Telnet. Automatic exit if the
program is inactive for the defined
time.
Values/Range
Integer
na (255)
Integer
DisplayString
(SIZE(0..32))
Integer
band_5_7GHz (1)
band_5_4GHz (2)
Values/Range
Integer
cancel (1)
resetSystemNow (2)
Integer
completeFactory (1)
partialFactory (2)
completeOperator (3)
partialOperator (4)
cancel (5)
DisplayString (SIZE(32))
A string of up to 32 printable
ASCII characters.
Integer
resetAndBootFrom
ShadowVersion (1)
useCurrentVersion
AfterReset (2)
cancel (3)
Integer
1-999 (minutes)