Sub Band Lower Frequency
The Sub Band Lower Frequency parameter defines the lowest frequency to
be used during the scanning process.
The range depends on the radio band of the unit, as shown in Table 5-4.
The resolution is 5 MHz.

Table 5-4: Ranges and Defaults for Sub Band Lower Frequency

Band
5.7 GHz
5.4 MHz
Sub Band Upper Frequency
The Sub Band Upper Frequency parameter defines the highest frequency
to be used during the scanning process.
The range depends on the radio band of the unit, as shown in Table 5-5.
The resolution is 5 MHz.
Table 5-5: Ranges and Defaults for Sub Band Upper Frequency
Band
5.7 GHz
5.4 MHz
Scanning Step
The Scanning Step parameter defines the resolution used for selecting
frequencies in the sub band defined by the Sub Band Lower Frequency
and the Sub Band Upper Frequency.
Valid values: 5, 10, 20 MHz.
Default value: 5 MHz.
Frequency Subset Definition
BreezeACCESS VL System Manual
Range
5740 – 5835 MHz
5485 – 5710 MHz
Range
5740 – 5835 MHz
5485 – 5710 MHz
Default
5740 MHz
5485 MHz
Default
5835 MHz
5710 MHz