Operator ESSID
The Operator ESSID parameter defines the Operator ESSID.
Valid values: A string of up to 31 printable ASCII characters.
The default value is ESSID1.
NOTE:
The Operator ESSID string is case-sensitive.
Frequency Definition Parameters
Frequency Definition Submenu in AU
The Frequency Definition submenu in AU includes a single parameter for
setting the transmit/receive frequency:
Frequency
The Frequency parameter defines the transmit/receive frequency. The
minimum distance between frequencies used by two neighboring AUs is
the Channel bandwidth, which is 20 MHz.
The range and default value depend on the radio band, as shown in Table
5-3. The frequency setting resolution is 5 MHz.

Table 5-3: Frequency Ranges and Defaults

Band
5.7 GHz
5.4 MHz
Frequency Definition Submenu in SU
To simplify the installation process the SU scans a definable frequencies
subset after power-up. If the Best AU feature is enabled, the SU will scan
the defined subset and the operating frequency will be determined by the
Best AU mechanism (including the optional use of the Preferred AU
feature). Otherwise the SU will try to associate with the first AU it finds.
The Frequency Definition submenu in SU includes the following
parameters:
Range
5740 – 5835 MHz
5780 MHz
5485 – 5710 MHz
Default
5600 MHz
5-29