Operation Verification

The following sections describe how to verify the correct functioning of the
Outdoor Units, Indoor Units, Ethernet connection and data connectivity.

Outdoor Unit Verification

To verify the correct operation of the Outdoor Unit, examine the LED
indicators located on the bottom panel of the outdoor unit.
The following tables list the provided LEDs and their associated
indications.
Name
Description
W-LINK
Wireless Link Indicator
DC Power
Self Test and Power
indication
ETH
Ethernet activity/
connectivity indication
SNR BAR
Received signal strength
(SU-RA)
Indication
Table 4-4: Outdoor Unit LEDs
Functionality
Blinking Green – Data received or transmitted on the
wireless link. Blinking rate is slower when there is less
wireless traffic.
Green – Power is available and self test passed.
Red – Self test failed. Firmware did not load
successfully.
Off –Ethernet connectivity is OK.
No traffic activity detected on the port.
Blinking Green –Ethernet connectivity is OK, with
traffic on the port.
Red – No Ethernet connectivity between the ondoor
and outdoor units.
10 green LEDs bar display indicating the level of the
received signal