7.7.10 Powering Up

The Canopy 150/300 Mb BH system is supplied as a pair of matched Master/Slave units.
The Master unit can now be powered up and accessed using the default URL
http://169.254.1.2
Prior to powering up the Canopy 150/300 Mb BH, a computer with web browsing capabilities
should be configured with an IP address of 169.254.1.n and subnet mask of 255.255.0.0
where n is any value between 1 and 254 but excluding 1 or 2. If the default address of the unit
169.254.1.1/2 clashes with an address you are already using on your LAN or you are not
sure, you should set up an isolated LAN. As the LAN connection presented at the 150/300
PIDU has a default configuration as a hub/switch (and auto-sensing MDI/MDIX cross over is
employed) connection can be made directly to the computer using a standard CAT 5 patch
cable.
Before physical installation takes place the units to be installed should be set up as described
in the section 8.3.3. This process will give the installer the opportunity to set the units IP
address to one that is in the desired address range and set each unit up with the MAC
address of its peer unit ready to establish a radio link. It is recommended that this procedure
be carried out on the bench before physical installation commences. Providing it is safe to do
so, the installer should take the process to the point where a radio link is established before
proceeding to the installation site.
Issue 1.1 April 2006
; the Slave unit can be accessed using
H
http://169.254.1.1
.
Page 46