11.3 EMC Emissions Compliance

Region
USA
Canada
Europe

11.4 EMC Immunity Compliance

Top-level Specification ETSI 301-489
Designed to comply with:
Specification
EN 55082-1 Generic EMC and EMI
requirements for Europe
EN 61000-4-2: 1995 Electro Static
Discharge (ESD), Class 2, 8 kV air, 4 kV
contact discharge
EN 61000-4-3: 1995 ENV50140: 1993
(radiated immunity) 3 V/m
EN 61000-4-4: 1995 (Bursts/Transients),
Class 4, 4 kV level (power lines AC & DC)
EN 6100045:1995, (Surge Immunity)
EN 61000-4-6: 1996 (Injected RF), power
line, Class 3 @ 10 V/m

11.5 Radio Certifications

Region
USA
14
Some Limitations on Power Output are needed to meet FCC Regulations.
T P
PT
Basic operating channels are numbered 0-9
Channels 1-8 can operate at 25dBm Max
Issue 1.1 April 2006
Specification
FCC Part 15 Class B
CSA Std C108.8, 1993 Class B
Designed to comply with EN55022 CISPR 22
Specification (Type Approvals)
FCC Part 15.247TPF14FPT
Comment
Testing will be carried to ensure immunity to
15kV air and 8kV contact
Signal lines @ 0.5 kV open circuit voltage.
Requires screened connection to users
network
Signal lines, Class 3 @ 3 V RMS un-
modulated.