Getting Started

3.1

For Your Safety

WARNING Use extreme care when installing antennas near power lines.
WARNING Use extreme care when working at heights.
WARNING The Canopy 150/300 Mbps Backhaul Outdoor unit (ODU) must be properly
grounded to protect against lightning. It is the user's responsibility to install the
equipment in accordance with Section 810 of the National Electric Code,
ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code. These
codes describe correct installation procedures for grounding the outdoor unit,
mast, lead-in wire and discharge unit, size of grounding conductors and
connection requirements for grounding electrodes. It is recommended that
installation of the outdoor unit be contracted to a professional installer.
WARNING The Canopy 150/300 Mbps Backhaul ODU MUST be grounded to a Protective
Earth as described in Section 7.7.6 "Grounding The Installation" of this
Installation Manual and in accordance with the Local Electrical Regulations.
WARNING It is recommended that the supplied 150/300 Mbps Backhaul Power Indoor Plus
(150/300 Mbps Backhaul PIDU) is used to power the 150/300 Mbps Backhaul
ODU. The use of other power sources may invalidate safety approval and affect
your warrantee.
WARNING When using alternate DC supplies (via the Canopy 150/300 Mbps Backhaul PIDU
DC in terminals as described in Section 3.2.3 "Redundancy and Alternate
Powering Configurations"), such as battery-backed DC power source, the supply
MUST comply with the following requirements:
CAUTION WHEN the system is operational, avoid standing directly in front of the antenna.
Strong RF fields are present when the transmitter is on. The Outdoor Unit must
not be deployed in a location where it is possible for people to stand or walk
inadvertently in front of the antenna.
CAUTION Users and installers should note that the mains power supply is the primary
disconnect device.
CAUTION SAFETY will be compromised if external quality cables are not used for
connections that will be exposed to the weather.
CAUTION Safety will be compromised if a different power supply is used than the one
supplied by Motorola as part of the system.
Issue 1.1 April 2006
The voltage and polarity is correct and is applied to the correct terminals in
the 150/300 Mbps Backhaul PIDU
The power source is rated as SELV
The power source is rated to supply at least 1A continuously, and
The power source cannot provide more than the Energy Hazard Limit as
defined by IEC/EN/UL6090, Clause 2.5, Limited Power (The Energy Hazard
Limit is 240VA)
Page 19