CHAPTER 2
This chapter describes each part and name of the head module.
2)
3)
4)
No.
Name
On
RUN LED
Flashing
Off
On
Flashing
REM. LED
1)
Off
On
ERR. LED
Flashing
Off
L ERR. LED
On
Off
20
PART NAMES
1)
6)
5)
7)
Indicates the operating status.
Operating normally (RUN status)
Working normally (STOP status)
• The switch of the head module has been set to STOP. (Transfer between the devices in the head module is stopped.)
• The Motion controller is in the STOP status. (Transfer between the devices in the head module is stopped.)
• Accepting a remote STOP request
• The head module has stopped due to an error (except a watchdog timer error).
A hardware failure or a watchdog timer error has occurred.
Indicates the operating status of the own station.
Operating normally
Has not been reset after writing to PLC. Or, forced input/output registration is in progress.
• The initial data are being processed.
• An error has occurred in the own station.
• SSCNET III/H disconnection
• Offline mode
Indicates the error status of the head module.
The error details can be checked with PLC diagnostics of GX Works2. ( Page 83, Section 11.2)
A head module failure or a watchdog timer error has occurred.
A station number setting switch setting error has occurred.
(Other than 1 to 64 is set for the station number setting switch.)
Working normally
Indicates the SSCNET III/H communication error status. The error details can be checked with SSCNET III Communication
Condition Monitor of MT Developer2. ( Page 77, CHAPTER 9)
A communication error has occurred.
Communicating normally