Mitsubishi Electric MELSEC-L SSCNETIII/H User Manual page 35

Melsec-l series, head module
Table of Contents

Advertisement

(3) Motion controller
The SSCNET III/H-compatible motion CPU and the stand-alone Motion controller are compatible.
Motion CPU
Stand-alone Motion controller
To connect the head module to the Motion controller, set the communication type
"SSCNET III/H". ("SSCNET III" is not available.)
*1
Set with "SSCNET Setting" in "Basic Setting" of MT Developer2.
(4) Software package
GX Works2 and MT Developer2 are required for setting and diagnosing the head module.
GX Developer is not available.
GX Works2
MT Developer2
(5) Precautions for system configuration
(a) Rated output current (5VDC)
Configure a system so that the total current consumption may not exceed 5VDC, rated output current of the
power supply module.
For specifications of the power supply module, refer to the following.
 MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
Module/unit
Software
CHAPTER 5 SYSTEM CONFIGURATION
Model name
R16MTCPU
R32MTCPU
R64MTCPU
Q172DSCPU
Q173DSCPU
Q170MSCPU
*1
of the Motion controller to
Version
Version 1.98C or later
Version 1.56J or later
5
33

Advertisement

Table of Contents
loading

Table of Contents