(a) When the I/O assignment setting for the head module is default
Motion controller
RX
0000
H
0000
H
to 000F
H
0010
H
to 001F
H
Station
0020
H
No.1
to 002F
H
0030
H
003F
H
to 003F
H
RY
0000
H
0000
H
to 000F
H
0010
H
to 001F
H
Station
0020
H
No.1
to 002F
H
0030
H
003F
H
to 003F
H
Slot No.
Slot 0
Start I/O No.
0000
Head module
16-point
Station No.1
input module
RX
X
0000
H
000F
H
RY
Y
0000
H
000F
H
CHAPTER 8 CYCLIC TRANSMISSION
Slot 1
0010
H
H
16-point
output module
input module
X
X
0000
0000
H
000F
000F
H
Y
Y
0000
0000
H
000F
000F
H
Slot 2
Slot 3
0020
0030
H
H
16-point
16-point
output module
X
X
0000
H
H
000F
H
H
Y
Y
0000
H
H
000F
H
H
67