(3) Drive information
No.
Name
Parameter
Write (transfer)
SD681
memory write
status display
(transfer) status
(percent)
SD682
Parameter
Write count
memory write
index up to the
SD683
count index
present
*1
The write count is not equal to the index value. (Since the maximum write count of the flash ROM has been increased by
the system, the value increments by 1 about every two write operations.)
(4) Debug
No.
Name
Debug function
Debug function
SD840
usage
usage status
(5) I/O module verification
No.
Name
SD1400
SD1401
SD1402
Bit pattern, in
SD1403
units of 16
SD1404
points,
indicating the
SD1405
modules with
SD1406
verification
I/O module
SD1407
errors
verify error
0:
SD1408
SD1409
to
1:
SD1430
SD1431
122
Description
Stores the progress of writing (transferring) to the parameter memory (flash ROM) in
percentage (0 to 100%). "0" is set when the write (transfer) command is issued.
Stores the index value of write count of the program memory (flash ROM)
present in 32-bit binary. When the index value exceeds 100 thousand times, "FLASH
ROM ERROR" (error code: 1610) occurs. (The index value will continue to be counted
even after it exceeds 100 thousand.)
Description
Stores the usage status of the following debug functions.
0: External input/output forced on/off function
1 to 15: Empty (fixed at 0)
(0: Not used 1: Used)
Description
• If the status of the I/O module changes from that obtained at power-on, the module No.
is stored in the following bit pattern. (If the I/O numbers are set by parameter, the
parameter-set numbers are stored.)
SD1400
SD1401
SD1431
No I/O
verification
When the number of I/O points of the module exceeds 16 points, all bits corresponding to
errors
the I/O module number (in units of 16 points) that is included in the number of I/O points
I/O
occupied by the module turn on.
verification
error exists
Example: When a 64-point module is connected on the slot 0, b0 to b3 are turned on by
error detection.
• Not cleared even if the normal state is restored. This flag is cleared by the error
resetting operation.
Details
Details
b15
to
b1 b0
0
Forced on/off function
for external I/O
Details
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
X Y
190
1
0
0
0
0
0
0
0
0
X Y
1FE0
Indicates an I/O module verification error
*1
up to the
1
0
0
0
0
0
0
X Y
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Set by (Set
timing)
S
(Write)
Set by (Set
timing)
S
(Status change)
Set by
(Set timing)
S
(On error)

Advertisement

Table of Contents
loading

Table of Contents