Sercnf (Serial Communication Configuration) - Omega DP41-S User Manual

High performance strain gage indicator
Hide thumbs Also See for DP41-S:
Table of Contents

Advertisement

9.2.19 SERCNF (Serial Communication Configuration)

Serial communication configuration is used to select:
• no parity, odd parity, or even parity for communications [SER.1]
• 1 stop bit or 2 stop bits [SER.2]
• No parity, 1 stop is not allowed
MENU
BUTTON
MAIN MENU
"SERCNF":
* The 'MIN' button allows you to toggle between SER.1 and SER.2.
The 'MAX' button allows you to select the "0", "1", or "2" state for each
"SER" condition.
The 'MENU' button stores the selected values for each "SER" condition
changed and advances the meter to the next configuration ("ADDRES").
Every underlined "0", "1" or "2" is the factory preset value.
Note
NOTE: Only 7 data bit communication is supported
Meter Function Menus
MIN/MAX/MENU *
BUTTON
SUB MENU
"SER.1=0"
"SER.1=1"
"SER.1=2"
"SER.2=0"
"SER.2=1"
DESCRIPTION
SERIAL COMMUNICATION
CONFIGURATION
Select parity for communications via
RS-232 or RS-485:
No parity
Odd parity
Even parity
Select stop bits for communications via
RS-232 or RS-485:
1 Stop Bit
2 Stop Bits
9