Maintenance; Maintenance Maintenance - Napoleon LVX38N Installation Manual

Luxuria series
Hide thumbs Also See for LVX38N:
Table of Contents

Advertisement

14.0 maintenance

maintenance
EN
WARNING
!
Turn off the gas and electrical power before servicing the appliance.
Appliance may be hot. Do not service until appliance has cooled.
Do not use abrasive cleaners on glass.
Do not paint the pilot assembly.
This appliance and its venting system should be inspected before use and at least annually by a qualifi ed
service person. The following suggested checks should be performed by a qualifi ed technician. The appliance
area must be kept clear and free of combustible materials, gasoline, or other fl ammable vapors and liquids.
The fl ow of combustion and ventilation air must not be obstructed.
note:
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
A. In order to properly clean the burner and pilot assembly, remove the logs, rocks, and/or glass to expose
both assemblies.
B. Keep the control compartment, media, burner, air shutter, opening, and the area surrounding the logs
clean by vacuuming or brushing at least once a year.
C. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are
not burning properly.
D. Check to see that the pilot fl ame reaches the sensor and large enough to engulf the fl ame sensor and/or
thermocouple or thermopile.
E. Replace the cleaned logs, rocks, or glass. Failure to properly position the media may cause carbon which
can be distributed inside of the fi rebox and on exterior surfaces surrounding vent termination.
F. Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10 second
total light-up period is satisfactory. Service as required.
G. Check the gaskets on the sides, top, and bottom of the door is not broken or missing. Replace if
necessary.
H. If for any reason the vent air intake system is disassembled, re-install, and re-seal per the instructions
provided for the initial installation.
Cleaning the safety barrier may be necessary due to excessive lint / dust from carpeting, pets, etc. Simply
I.
vacuum using the brush attachment.
J. Ensure the relief system performs effectively. Check that the gasket is not worn or damaged. Replace if
necessary.
66
W415-1710 / A / 07.27.17
24.3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents