11.0 finish framing - after appliance installation
11.1 framing with Dynamic Heat Control™
note:
Appliances equipped with Dynamic Heat Control™ can be built in with combustible framing and finishing un-
less stated.
There are various methods to ventilate the enclosure. Refer to "Dynamic Heat Control™ planning" section.
The appliance must be installed at this point of framing. Appliance is not shown to better illustrate finish framing.
single-sided flush
note:
Finish framing must be built after
appliance has been placed in its
final position and
venting connected.
Although the minimum enclosure
height for the LVX series is 73",
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.
Option 2 illustrated (appliance not shown)
minimum framing
Ref
LVX38
K
39 15/16" (101.4cm)
E
18" (45.7cm)
53 13/16" (136.7cm)
F
J
73" (185.4cm)
L
Q*
(Q x R)*
* ONLY APPLICABLE TO OPTION 2 AND 3 - Opening must be centered in enclosure on appliance. Dimensions represent
finished sizes and where applicable should be adjusted to include finish material thickness.
finish framing - after appliance installation
Ceiling
L
J
LVX50
39 15/16" (101.4cm)
18" (45.7cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
2" min and 3" max
80 sq. in.
R
Q
K
E
F
Insulation
LVX62
39 15/16" (101.4cm)
18" (45.7cm)
77 13/16" (197.6cm)
91" (231.1cm)
160 sq. in.
EN
Drywall
LVX74
39 15/16" (101.4cm)
18" (45.7cm)
89 13/16" (228.1cm)
91" (231.1cm)