Napoleon LVX38N Installation Manual page 31

Luxuria series
Hide thumbs Also See for LVX38N:
Table of Contents

Advertisement

Before framing your appliance, determine vent requirements before deciding the final location of the appliance.
After rough framing, place the appliance in its final position.
single-sided
L
J
Ref
LVX38
18" (45.7cm)
E
F
53 13/16" (136.7cm)
J
L
73" (185.4cm)
see-thru
Ref
LVX38
16 3/16" (41.1cm)
E
F
53 13/16" (136.7cm)
J
L
73" (185.4cm)
rough framing - before appliance installation
E
F
LVX50
18" (45.7cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
E
F
LVX50
16 3/16" (41.1cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
note:
Although the minimum enclosure
height for the LVX series is 73",
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.
LVX62
18" (45.7cm)
77 13/16" (197.6cm)
91" (231.1cm)
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
note:
Although the minimum enclo-
sure height for the LVX series is
73", some venting configurations
that require more vertical rise will
L
require a larger enclosure to pro-
vide minimum vertical clearance
between vent pipes and combus-
tibles.
J
LVX62
16 3/16" (41.1cm)
77 13/16" (197.6cm)
91" (231.1cm)
EN
LVX74
18" (45.7cm)
89 13/16" (228.1cm)
91" (231.1cm)
LVX74
16 3/16" (41.1cm)
89 13/16" (228.1cm)
91" (231.1cm)
31
W415-1710 / A / 07.27.17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents