8.4.1 Avoidance of Condensation

If environmental conditions makes water cooling necessary, it is strictly recommended to check
whether condensation will be a real problem or not. Water cooling also causes a cooling of the air in
the inner part of the sensor, thereby decreasing the capability of the air to hold water. The relative
humidity increases and can reach 100% very quickly. In case of a further cooling, the surplus water
vapor will condense out as water. The water will condense on the lenses and the electronics resulting
in possible damage to the sensor. Condensation can even happen on an IP65 sealed housing.
To avoid condensation, the temperature of the cooling media and the flow rate must be selected to
ensure a minimum device temperature. The minimum sensor temperature depends on the ambient
temperature and the relative humidity. Please consider the following table.
Example:
Ambient temperature
Relative humidity
Minimum device temperature = 30 °C
The use of lower temperatures is at your own risk!
ENDURANCE 1R
info@Raytek-Direct.ca
There is no warranty repair possible in case of condensation within the housing!
10
15
20
25
30
0/
0/
0/
0/
0/
0/
32
32
32
32
32
32
5/
0/
0/
0/
0/
0/
41
32
32
32
32
32
10/
0/
0/
0/
0/
0/
50
32
32
32
32
32
15/
0/
0/
0/
0/
0/
59
32
32
32
32
32
20/
0/
0/
0/
0/
0/
68
32
32
32
32
32
25/
0/
0/
0/
0/
5/
77
32
32
32
32
41
30/
0/
0/
0/
5/
5/
86
32
32
32
41
41
35/
0/
0/
5/
10/
10/
95
32
32
41
50
50
40/
0/
5/
10/
10/
15/
104
32
41
50
50
59
45/
0/
10/
15/
15/
20/
113
32
50
59
59
68
50/
5/
10/
15/
20/
25/
122
41
50
59
68
77
60/
15/
20/
25/
30/
30/
140
59
68
77
86
86
70/
20/
25/
35/
35/
40/
158
68
77
95
95
104
80/
25/
35/
40/
45/
50/
176
77
95
104
113
122
90/
35/
40/
50/
50/
50/
194
95
104
122
122
122
100/
40/
50/
50/
60/
60/
212
104
122
122
140
140
Tab. 3: Minimum device temperatures [°C/°F]
Relative Humidity [%]
35
40
45
50
55
0/
0/
0/
0/
0/
32
32
32
32
32
0/
0/
0/
0/
0/
32
32
32
32
32
0/
0/
0/
0/
0/
32
32
32
32
32
0/
0/
0/
0/
5/
32
32
32
32
41
0/
5/
5/
5/
10/
32
41
41
41
50
5/
10/
10/
10/
10/
41
50
50
50
50
10/
10/
15/
15/
15/
50
50
59
59
59
15/
15/
20/
20/
20/
59
59
68
68
68
20/
20/
20/
25/
25/
68
68
68
77
77
25/
25/
25/
30/
30/
77
77
77
86
86
25/
30/
30/
35/
35/
77
86
86
95
95
35/
40/
40/
40/
45/
95
104
104
104
113
45/
45/
50/
50/
50/
113
113
122
122
122
50/
50/
60/
60/
60/
122
122
140
140
140
60/
60/
60/
140
140
140
= 50 °C
= 40 %
Rev. E1 Sep 2015
60
65
70
75
80
85
0/
0/
0/
0/
0/
0/
32
32
32
32
32
32
0/
0/
0/
0/
0/
0/
32
32
32
32
32
32
0/
0/
0/
5/
5/
5/
32
32
32
41
41
41
5/
5/
5/
10/
10/
10/
41
41
41
50
50
50
10/
10/
10/
15/
15/
15/
50
50
50
59
59
59
15/
15/
15/
20/
20/
20/
59
59
59
68
68
68
20/
20/
20/
20/
25/
25/
68
68
68
68
77
77
25/
25/
25/
25/
30/
30/
77
77
77
77
86
86
25/
30/
30/
30/
35/
35/
77
86
86
86
95
95
35/
35/
35/
35/
40/
40/
95
95
95
95
104
104
35/
40/
40/
40/
45/
45/
95
104
104
104
113
113
45/
50/
50/
50/
50/
50/
113
122
122
122
122
122
50/
50/
60/
60/
60/
60/
122
122
140
140
140
140
60/
60/
140
140
Temperatures
higher
(149°F) are not recommended due to
the temperature limitation of the
sensor.
Options
90
95
100
0/
0/
0/
32
32
32
0/
0/
5/
32
32
41
5/
5/
10/
41
41
50
10/
10/
15/
50
50
59
15/
15/
20/
59
59
68
20/
20/
25/
68
68
77
25/
25/
30/
77
77
86
30/
30/
35/
86
86
95
35/
35/
40/
95
95
104
40/
40/
45/
104
104
113
45/
45/
50/
113
113
122
50/
50/
60/
122
122
140
60/
60/
140
140
than
65°C
43
1.800.868.7495

Advertisement

Table of Contents
loading

This manual is also suitable for:

Endurance 1rh

Table of Contents